package main import ( "context" "crypto/md5" "embed" "encoding/hex" "flag" "fmt" "io" "io/fs" "os" "os/exec" "path/filepath" "runtime" "time" "bj_power_workstation/internal/alertstream" "bj_power_workstation/internal/config" "bj_power_workstation/internal/handler" "bj_power_workstation/internal/mes" "bj_power_workstation/internal/pdfcache" "bj_power_workstation/internal/store" "bj_power_workstation/internal/svc" "bj_power_workstation/internal/syncer" "bj_power_workstation/internal/tightening" "bj_power_workstation/internal/scanbridge" "github.com/zeromicro/go-zero/core/conf" "github.com/zeromicro/go-zero/core/logx" "github.com/zeromicro/go-zero/rest" ) //go:embed all:web/static var webFS embed.FS var configFile = flag.String("f", "etc/bj_power_workstation.yaml", "the config file") // openBrowser 用系统默认浏览器打开 url(Windows/macOS/Linux) func openBrowser(url string) { var cmd *exec.Cmd switch runtime.GOOS { case "windows": cmd = exec.Command("rundll32", "url.dll,FileProtocolHandler", url) case "darwin": cmd = exec.Command("open", url) default: cmd = exec.Command("xdg-open", url) } if err := cmd.Start(); err != nil { logx.Errorf("自动打开浏览器失败(%s): %v", url, err) } } // logRuntimeBinaryFingerprint 在启动早期打印当前运行 EXE 的指纹(真实路径/大小/MD5/修改时间), // 走本项目 logx(go-zero)落盘,与业务日志同文件,便于生产机直接翻日志核对运行版本。 // 任何环节失败仅记错误日志并继续,绝不中断启动。 func logRuntimeBinaryFingerprint() { exePath, err := os.Executable() if err != nil { logx.Errorf("svc: runtime binary fingerprint skipped: os.Executable failed: %v", err) return } realPath, err := filepath.EvalSymlinks(exePath) if err != nil { // 解析软链接失败:降级用原始路径,仅记日志不影响启动 logx.Errorf("svc: runtime binary fingerprint: EvalSymlinks failed, fallback to raw path: %v", err) realPath = exePath } info, err := os.Stat(realPath) if err != nil { logx.Errorf("svc: runtime binary fingerprint skipped: os.Stat failed: %v", err) return } f, err := os.Open(realPath) if err != nil { logx.Errorf("svc: runtime binary fingerprint skipped: open failed: %v", err) return } defer f.Close() h := md5.New() if _, err := io.Copy(h, f); err != nil { logx.Errorf("svc: runtime binary fingerprint skipped: read failed: %v", err) return } logx.Infof("svc: runtime binary fingerprint path=%s size=%d md5=%s modTime=%s", realPath, info.Size(), hex.EncodeToString(h.Sum(nil)), info.ModTime().Format("2006-01-02 15:04:05")) } func main() { flag.Parse() var c config.Config conf.MustLoad(*configFile, &c) // 启动指纹:打印当前 EXE 真实路径/大小/MD5/修改时间,便于核对运行版本 logRuntimeBinaryFingerprint() // 工位号:由服务端配置文件加载(终端不允许修改)。0=上线位、13=下线位为虚拟工位 // (PAD 上线建档 / 下线完工),1~12 为物理装配工位;启动时强校验 >= 0(工位数以数据库/配置为准,不写死 12)。 if c.Station.StationNo < 0 { panic(fmt.Sprintf("Station.StationNo 必须 >= 0,当前配置为 %d(请修改 yaml 后重启)", c.Station.StationNo)) } logx.Infof("固定工位号: %d", c.Station.StationNo) staticFS, err := fs.Sub(webFS, "web/static") if err != nil { panic(fmt.Sprintf("加载内嵌前端资源失败: %v", err)) } // 本地 SQLite:拧紧数据缓存 + 离线上报队列 + 操作日志 + 内置账号 st, err := store.Open(c.Sqlite.Path) if err != nil { panic(fmt.Sprintf("打开本地 SQLite(%s) 失败: %v", c.Sqlite.Path, err)) } defer st.Close() if err := store.SeedIfEmpty(st); err != nil { panic(fmt.Sprintf("初始化内置用户失败: %v", err)) } rootCtx, cancel := context.WithCancel(context.Background()) defer cancel() mc := mes.New(c.Mes.BaseURL, c.Internal.Token) // 核实4:绑定空闲计时回调——每次以有效登录态发起的 MES 调用刷新 last_active_at, // 证明当前操作人仍活跃在岗,后台 sweeper 据此判断是否超时自动登出。 mc.Touch = func() { _ = st.TouchStationSession() } // 后台同步协程:联网时向 MES 补报未同步数据 sy := syncer.New(st, mc) sy.SetBacklogThreshold(c.Backlog.WarnThreshold) // 建议1:积压告警阈值可配置(yaml backlog.warnThreshold) go sy.Run(rootCtx) // 核实4:空闲自动登出 sweeper——周期性检查登录态空闲时长,超过 IdleLogoutSeconds 则清除 // 本地登录态并失效 Bearer 凭证,强制换班/下一班操作工重新登录,杜绝共享终端身份错位。 go func() { ticker := time.NewTicker(60 * time.Second) defer ticker.Stop() for { select { case <-rootCtx.Done(): return case <-ticker.C: cleared, err := st.ClearExpiredSession(c.Station.IdleLogoutSeconds) if err != nil { logx.Errorf("检查工位登录态空闲超时失败: %v", err) continue } if cleared { logx.Infof("工位登录态空闲超过 %d 秒,已自动登出", c.Station.IdleLogoutSeconds) mc.SetStationToken("") } } } }() // 拧紧枪 OP 接入(阿特拉斯 Open Protocol):Enable=true 时后台长连接控制器,接收拧紧结果暂存, // 操作工在界面点「完成」才经 POST /api/tightening/record 落本地库并上报 MES;Enable=false 时仍走人工录入。 tm := tightening.NewManager(c.Tightening) go tm.Run(rootCtx) // 工位报警事件流(谁受影响谁播报,2026-10-20):长连接 MES SSE,按本机工位过滤后广播给本机前端; // 断线自动重连;前端 EventSource 订阅 /api/alerts/stream,断线重连后一次性补拉 /api/alerts/station。 am := alertstream.New(mc, c.Station.StationNo) go am.Run(rootCtx) // 扫码中间件(键盘 HID 注入):Enable=true 时后台监听 7757,接收网络型扫码枪(iData PAD / 新大陆手机) // 推送并模拟键盘注入当前光标窗口(任意输入框自动填入,前端无需轮询)。7757 被占用时仅记日志、不影响主程序。 if c.Scanner.Enabled { go func() { if err := scanbridge.Start(rootCtx, scanbridge.Options{}); err != nil { logx.Errorf("扫码中间件启动失败(不影响主程序): %v", err) } }() } // 工艺文件 PDF 本地预缓存 pdc := pdfcache.New(c.PdfCache.Dir) ctx := &svc.ServiceContext{ Config: c, Store: st, Mes: mc, Syncer: sy, PdfCache: pdc, WebFS: staticFS, Tightening: tm, AlertStream: am, } server := rest.MustNewServer(c.RestConf) defer server.Stop() handler.RegisterHandlers(server, ctx) fmt.Printf("Starting bj_power_workstation server at %s:%d...\n", c.Host, c.Port) logx.Infof("Starting bj_power_workstation server at %s:%d...", c.Host, c.Port) // 启动后自动打开终端页面(等 1 秒让端口就绪;Host=0.0.0.0 时用 127.0.0.1 访问) go func() { time.Sleep(time.Second) openBrowser(fmt.Sprintf("http://127.0.0.1:%d", c.Port)) }() server.Start() }