feat: 重构视觉取料流程及生产故障恢复
- 删除订单启动、暂停、复位相关 PLC 握手及无效反馈配置 - 清除报警改为仅写 clearAlarmCommand,不等待反馈 - 将拍照位移动、视觉处理和 RackPick 拆分为三个独立动作 - 增加 M850/M851 拍照位动作及 R60/M852 视觉结果流程 - 暂停改为等待当前机器人动作完成,视觉结果不确定时转人工确认 - 删除复位按钮,合并为恢复/重试按钮 - 普通 PAUSED 订单通过启动按钮继续 - 恢复前检查 PLC、安全状态、订单及动作命令反馈 - 支持在途动作接管、已完成动作收尾、安全重试和人工确认 - 故障状态保持订单 RUNNING,并持久化实际恢复阶段 - 恢复成功后仅清除本次软件故障对应的报警 - 更新小轴 PLC 地址、Modbus 配置和视觉集成文档
This commit is contained in:
+35
-32
@@ -17,14 +17,9 @@ pollIntervalMs=1000
|
||||
feedbackTimeoutMs=2000
|
||||
reconnectDelayMs=200
|
||||
reconnectAttempts=2
|
||||
startCommand=0
|
||||
pauseCommand=1
|
||||
resetCommand=2
|
||||
|
||||
; Coils
|
||||
clearAlarmCommand=3
|
||||
startFeedback=10
|
||||
pauseFeedback=11
|
||||
resetFeedback=12
|
||||
clearAlarmFeedback=13
|
||||
plcReady=100
|
||||
robotReady=101
|
||||
safetyDoorClosed=102
|
||||
@@ -40,25 +35,40 @@ activeAlarm=507
|
||||
currentStep=200
|
||||
checkResult=201
|
||||
errorCode=202
|
||||
rackPickCommand=300
|
||||
rackPickFeedback=310
|
||||
frontLoadCommand=301
|
||||
frontLoadFeedback=311
|
||||
|
||||
;robot signals
|
||||
rackPickCommand=800
|
||||
rackPickFeedback=807
|
||||
frontLoadCommand=803
|
||||
frontLoadFeedback=810
|
||||
inspectionCommand=302
|
||||
inspectionFeedback=312
|
||||
frontUnloadCommand=303
|
||||
frontUnloadFeedback=313
|
||||
flipCommand=304
|
||||
flipFeedback=314
|
||||
backLoadCommand=305
|
||||
backLoadFeedback=315
|
||||
backUnloadCommand=306
|
||||
backUnloadFeedback=316
|
||||
rackPlaceCommand=307
|
||||
rackPlaceFeedback=317
|
||||
inspectionMode=320
|
||||
trayNumber=400
|
||||
slotNumber=401
|
||||
frontUnloadCommand=802
|
||||
frontUnloadFeedback=809
|
||||
flipCommand=804
|
||||
flipFeedback=811
|
||||
backLoadCommand=806
|
||||
backLoadFeedback=813
|
||||
backUnloadCommand=805
|
||||
backUnloadFeedback=812
|
||||
rackPlaceCommand=801
|
||||
rackPlaceFeedback=808
|
||||
inspectionMode=814
|
||||
|
||||
photoMoveCoil=850
|
||||
photoMoveCoilFeedback=851
|
||||
comparisonPickCoil=852
|
||||
|
||||
|
||||
;holdregister
|
||||
slotNumber=800
|
||||
trayNumber=801
|
||||
slotRowNumber=802
|
||||
slotColumNumber=803
|
||||
; R indices, not raw Modbus addresses (R40=12328, R60=12348).
|
||||
photoPoseR=40
|
||||
graspPoseR=60
|
||||
lowWordFirst=true
|
||||
|
||||
[production]
|
||||
loadStep=1
|
||||
@@ -82,7 +92,7 @@ productionEnabled=true
|
||||
|
||||
[vision]
|
||||
; Recognition switch only; the M850/M851 photo-position stage always precedes RackPick.
|
||||
enabled=false
|
||||
enabled=true
|
||||
contractConfirmed=true
|
||||
photoPoseReadyConfirmed=true
|
||||
executablePath=E:/QTCode/VisionGuide/VisionGuide_Qt/source/build-ssp-integration/bin/VisionGuide.exe
|
||||
@@ -90,13 +100,6 @@ ipcName=ssp_visionguide_v1
|
||||
startupTimeoutMs=15000
|
||||
initializeTimeoutMs=60000
|
||||
requestTimeoutMs=15000
|
||||
photoPoseR=40
|
||||
graspPoseR=60
|
||||
lowWordFirst=true
|
||||
photoMoveCoil=850
|
||||
photoArrivedCoil=851
|
||||
comparisonPickCoil=852
|
||||
; ssp clears M850/M851 after arrival; M852 is overwritten before each RackPick and retained.
|
||||
|
||||
[visionTrayMap]
|
||||
; All six physical trays use VisionGuide configuration 1.
|
||||
|
||||
Reference in New Issue