Files
ssp/config.ini
T
lidg a7af930a0a feat(vision): 新增拍照到位前置流程并支持视觉失败降级取料
- 在普通 RackPick 前写托盘号、格位并置 M850,收到 M851 后清除两位
- 使用 vision/enabled 控制识别,关闭时仍执行拍照到位流程
- 识别成功且 R60 写入确认后写 M852=1,视觉关闭或失败时写 M852=0
- 确认 M852 写入后启动 RackPick,动作结束保留 M852
- 移除旧 850–854 五信号握手,更新配置和协议文档
- 允许未就绪的视觉服务接收测量,扩展超时以覆盖初始化重试
- 保留 PLC 写入失败阻断、暂停发送门控及迟到结果拒绝
- 持久化未完成事务,支持 PLC 暂停后的视觉维护与人工恢复

验证:MinGW 32/64 位编译通过;生产流程47、IPC14、PLC11项测试通过
2026-10-28 15:19:18 +08:00

109 lines
2.0 KiB
INI

[database]
driver=QPSQL
host=127.0.0.1
port=5432
name=ssp
user=postgres
password=hardman
connection=ssp_postgres
[modbus]
host=127.0.0.1
port=502
serverAddress=1
timeoutMs=1000
retryCount=1
pollIntervalMs=1000
feedbackTimeoutMs=2000
reconnectDelayMs=200
reconnectAttempts=2
startCommand=0
pauseCommand=1
resetCommand=2
clearAlarmCommand=3
startFeedback=10
pauseFeedback=11
resetFeedback=12
clearAlarmFeedback=13
plcReady=100
robotReady=101
safetyDoorClosed=102
emergencyStop=103
inspectionMachineReady=500
visionReady=501
robotControlCabinetReady=502
mainControlCabinetReady=503
safetyDoor1Closed=504
safetyDoor2Closed=505
safetyDoor3Closed=506
activeAlarm=507
currentStep=200
checkResult=201
errorCode=202
rackPickCommand=300
rackPickFeedback=310
frontLoadCommand=301
frontLoadFeedback=311
inspectionCommand=302
inspectionFeedback=312
frontUnloadCommand=303
frontUnloadFeedback=313
flipCommand=304
flipFeedback=314
backLoadCommand=305
backLoadFeedback=315
backUnloadCommand=306
backUnloadFeedback=316
rackPlaceCommand=307
rackPlaceFeedback=317
inspectionMode=320
trayNumber=400
slotNumber=401
[production]
loadStep=1
frontCheckStep=2
backCheckStep=3
unloadStep=4
cycleCompleteStep=5
okResult=1
ngResult=2
errorResult=3
simulationResult=1
timeoutWarningMs=8000
stateTimeoutMs=10000
maxRecoveryRetries=1
simulationStepMs=500
usePlcErrorCode=false
[system]
simulation=false
productionEnabled=true
[vision]
; Recognition switch only; the M850/M851 photo-position stage always precedes RackPick.
enabled=false
contractConfirmed=true
photoPoseReadyConfirmed=true
executablePath=E:/QTCode/VisionGuide/VisionGuide_Qt/source/build-ssp-integration/bin/VisionGuide.exe
ipcName=ssp_visionguide_v1
startupTimeoutMs=15000
initializeTimeoutMs=60000
requestTimeoutMs=15000
photoPoseR=40
graspPoseR=60
lowWordFirst=true
photoMoveCoil=850
photoArrivedCoil=851
comparisonPickCoil=852
; ssp clears M850/M851 after arrival; M852 is overwritten before each RackPick and retained.
[visionTrayMap]
; All six physical trays use VisionGuide configuration 1.
1=1
2=1
3=1
4=1
5=1
6=1